Shanghai Youhuan Transmission Machinery Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Yu Candice
  • Company Name : Shanghai Youhuan Transmission Machinery Co., Ltd.
  • Tel : 86-21-66580117
  • Fax : 86-21-56555311
  • Address : Shanghai,Shanghai,Floor 1901,No12 Building,#938 Datong Road,Zhabei District
  • Country/Region : China

Helix manual nozzle with flowmeter

Helix manual nozzle with flowmeter
Product Detailed
Related Categories:Fuel Systems
Manual nozzle with flowmeter(oil-filling gun) It is suitalbe for gasoline and kerosene fuel High accuracy,Convenient,Easy use

Helix Manual nozzle with flowmeter

I.usage

LLY series of manual nozzle with flowmeter (abbreviated as oil-filling gun) is a meter used to measure the volume flow rate of liquid passing through the pipe. It is suitable for measuring gasoline and kerosene fuel etc. The meter has such advantages as high accuracy and convenient and flexible use. As long as there is a height difference of 2m to 10m between the liquid level of measured medium and the meter, it can operate normally without any additional power source.

II. Main technical parameters

This product which had been set up a file by the province standard measurement bureau, with the number of Q33N212504-90, produces according to the Q/YOY01-90 standard organization; its main technology parameter as below:

1. Nominal diameter and flow rate:

Model

Nominal diameter (mm)

Minimum flow rate (L/min)

Rated flow rate (L/min)

Maximum flow rate (L/min)

Display value of meter

LLY-15 model

15

15

25

40

1~9999

LLY-25 model

25

25

35

60

1~9999

LLY-32 model

32

32

65

120

1~9999

2. Metering accuracy: ±1%

3. Measured medium: gasoline. If the medium is kerosene or diesel oil, the readings of flow meter shall be corrected. Refer to article 5 of clause 4 for details.

4. Maximum working pressure: 0.1MPa

III. Main structure and working principle

The manual nozzle with flowmeteris composed of Counter, metering chamber and main body etc. three parts. Among them, the electronic digital displayer is composed of magnetic coupler, accumulation indicator and zero-resetting device etc. mechanism. The metering chamber is composed of core rack, impeller, worm wheel and worm. The main body is composed of meter shell, oil inlet and outlet tank and valve mechanism etc.

Grasp firmly the bending handle. When the valve opens, the liquid will pass through the oil tank and flow into the metering chamber, and under the action of liquid, the impeller will produce torque to rotate. The rotation speed of impeller will be reduced by worm wheel, worm and gear, and driven by the magnetic coupler, the electronic digital displayer will carry out calculation, so that the volume quantity of liquid passing through the pipe can be read out.

 

1.       Oil inlet pipe 

2.       Rubber cushion

3.       Core rack

4.       Impeller

5.       zero-resetting

6.       accumulation instructs

7.       Magnetic coupler

8.       Worm wheel

9.       Valve mechanism

10.   Oil outlet pipe

11.   Bending handle

12.   body

13.   Adjuster

IV. Detailed rules for use and installation

Before installation, the liquid transporting pipe and rubber hose shall be cleaned, and then connect the rubber hose with the pipe connector of manual nozzle with flowmeter and fasten it to start the use. LLY-25 model or LLY-32 model indicates that rubber hose with inside diameter of Φ25 or Φ32 can be used for connection.

1.       The flow value of measured medium in the pipe shall be within the flow range stipulated by the metering oil-filling gun. Refer to article 1 of clause 2 for details.

2.       The liquid level of measured liquid shall be 2-10m higher than the flow meter.

3.       The metering oil-filling gun shall be installed with “filtering device” at its front so as to guarantee the cleanliness of liquid. The “filtering device” can adopt steel wire cloth of at lease 20 meshes, and the total area shall be more than 75mm for filtering the liquid.

4.       The metering oil-filling gun is a relatively precise meter, which is forbidden to be knocked or beaten. In case of any malfunction of the meter, please first get familiar with the structure, then carry out sequential disassembly and inspection carefully, and calibrate and check again after the disassembly.

(1)    The precision of standard vessel shall not be less than ±0.2%.

(2)    When calibrating, select low, middle and high etc. three points within the flow range of the meter and carry out test thrice at each point, then take the average value.

The metering precision of meter shall be calculated according to the following formula:

E=  Vmeter-Vstandard   ×100%

        Vstandard

In the formula: E --- metering precision

            Vmeter --- display value of meter

            Vstandard --- display value of standard vessel

During the calibration, if it is necessary to adjust the meter precision, please disassemble the lead seal, remove the screw of lead seal, then screw off the fastening screw, and screw in the adjusting screw, which is positive, and screw out the adjusting screw, which is negative. After the adjustment assemble them in turn, and the meter after the calibration shall meet the requirements of precision.

5.       The oil-filling gun is velocity type meter so the change of viscosity and density of medium will affect the display value of meter. When leaving the factory, the gasoline (or simulated gasoline) is used as calibrating medium. Therefore, when measuring kerosene or diesel oil, the display value of meter shall be corrected. If the condition permits, users shall calibrate it again under the working condition. The viscosity of kerosene may be greatly affected by the temperature; hence, difference may exist in the corrected coefficients under different temperatures. The corrected coefficients deducted after experiment will be recommended to users.

The calculation formula is as follows:

Actual oil filling amount: corrected coefficient×display value of flow meter (liter)

Corrected coefficient: (1) If the medium is kerosene, the corrected coefficient equals to 0.994.

(2) If the medium is diesel oil and the oil temperature is more than 10°C, the corrected coefficient equals to 0.978.

If the medium is diesel oil and the oil temperature is less than or equal to 10°C, the corrected coefficient equals to 0.957.

(Application instance): when measuring the diesel oil, the oil temperature is 13°C, the display value on the meter panel of oil-filling gun is 150 liters, what is the actual oil filling amount?

Actual oil filling amount=0.978×150 liters=146.7 liters

Answer: the actual oil filling amount is 146.7 liters.

6.       Installation figure

Helix manual nozzle with flowmeter



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.